AS/NZS 3008/3000


AS/NZS 3008/3000

Australian/New Zealand Standard 3008/3000

概述

Australian/New Zealand Standard 3008 based "electrical installations and selection of cables" is listed as "AS 3008" and "NZS 3008". AS 3008 is for Part 1.1: Cables of alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions. NZS 3008 is for Part1.2: Cables of alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions.

ETAP AS/NZS 3008/3000 Cable Sizing & Shock Protection provides a comprehensive and accurate module in compliance with the latest AS/NZS 3008/3000 standard for design and sizing of low voltage cables. ETAP Cable Sizing software suite offers powerful features to save time and improve accuracy for cable calculation and electrical design of phase, neutral and earth conductors.

Australian New Zealand Standard 3008 icon

AS/NZS 3008/3000 Key Features

  • User selectable Standard for either Australian installation conditions (AS 3008) or New Zealand installation conditions (NZS 3008).
  • Current carrying capability and correction factors from standard tables.
  • Detailed installation types and sub types based on schedule of installation methods.
  • Consideration of ambient temperature, installation layout, grouping, soil, and other conditions.
  • Consideration of Loading, Voltage Drop, Overload Protection, Short Circuit, and Harmonic conditions for cable sizing.
  • Fully integrated with Load Flow, Short Circuit & Protective Device Coordination modules
  • Current Carrying Capacity, Sizing and Summary reports.
  • Complete Thermal Sizing & Electric Shock Protection module (AS/NZS 3000)
  • Consideration of Let Through Energy Capability for cable sizing.

AS/NZS 3008/3000 Benefits

  • Quickly and accurately size Phase, Neutral and Protective Conductors per compliance with AS/NZS 3008/3000
  • Review input data, calculation results, and alerts for multiple cables in a consolidated fashion through the Cable Manager.
  • Generate Cable Ampacity and Sizing reports simultaneously for multiple cables with a click of a button.

Cable Installations

ETAP’s cable current capacity calculation handles both above ground (A/G) and underground (U/G in duct and buried) installations:

  • A/G Conduit (thermally insulated wall, attached to wall, masonry, unventilated or ventilated channel)
  • A/G Trays (perforated, unperforated)
  • Air Drop (suspended, on insulators)
  • Brackets
  • Embedded Direct (thermally insulated wall, mouldings, masonry)
  • Ladder
  • Wire Mesh
  • Open & Clipped Direct (on wall, under ceiling, spaced from ceiling)
  • Trunking (on wall, suspended, flush floor, skirting)
  • U/G Duct
  • U/G Buried (direct, conduit)
  • Masonry (cable ducting)

相关产品

探索附加组件和其他相关产品。

查看所有产品

Electric Shock Protection

Integrated Short Circuit & Electric Shock Protection Calculations.

相关解决方案

了解重点介绍该产品的解决方案。

查看所有解决方案

相关软件包

查找包含该产品作为其集合一部分的包装束。

查看所有套餐

相关行业

了解该产品在各个行业中的应用。

查看所有行业

Oil & Gas

Oil and gas exploration leads companies to some of the most remote, inhospitable locations on Earth in search of energy

相关系统

了解该产品在工程系统中的用途。

查看所有系统

评价

常见问题解答

    培训与活动

    ETAP Training

    培训与活动

    通过申请适合您的培训课程来深入了解我们的电气工程软件。

    立即探索

    Try ETAP Demo

    立即探索 ETAP

    免费试用 ETAP 30 天,亲自体验 ETAP 解决方案的功能
    。在此基于云的演示平台上随时随地试用 ETAP 丰富的模块集合和分析结果
    。立即开始您的在线演示!