Produits phares
Liens rapides
With the Harmonic Analysis module, you can simulate harmonic current and voltage sources, identify harmonic problems, reduce nuisance trips, design and test filters, and report harmonic voltage and current distortion limit violations.
Comprehensive load flow and frequency scan calculations are performed using detailed harmonic source models and power system component frequency models. Results are shown graphically, including harmonic order, harmonic spectrum plots, and harmonic waveform plots, as well as Crystal Reports.Complied Harmonic Standards:
Découvrez les modules complémentaires et autres produits associés.
Voir tous les produits
Découvrez des solutions dans lesquelles ce produit est mis en avant.
Voir toutes les solutions
Recherchez un pack comprenant ce produit dans sa collection.
Voir tous les forfaits
Découvrez comment ce produit est utilisé dans diverses industries.
Voir tous les secteurs d'activité
Découvrez les utilisations de ce produit dans un système d’ingénierie.
Voir tous les systèmes
Voir toutes les ressources
This presentation aims to explain the necessary steps to comply with national grid code standards; an exemplary case of a steel manufacturing plant with intensive use of induction furnaces and a THD that exceeded the Grid Code's limits. This presentation highlights compliance, analysis, engineering (electrical power system studies), and equipment designed to comply with the technical criteria and mitigation. ETAP was used to size a filter to mitigate harmonics and improve the power factor for 34.5 kV transformers for grid code compliance.
Learn how engineers use ETAP Harmonic Analysis software to simulate harmonic current and voltage sources, identify harmonic problems, reduce nuisance trips, design, and test filters, and report harmonic voltage and current distortion limit violations on balanced or unbalanced systems. Additionally, for transmission and distribution system operators, Harmonic Grid Code automates harmonic analysis for detailed power quality assessment reporting demonstrating the generation facility is designed to comply with applicable harmonic limits. Study reports include worst-case incremental and total harmonic distortion, frequency-dependent Thevenin Equivalent at PCC, and color-coded impedance loci charts.
This webinar presents the fundamentals of harmonics, harmonic distortion and its sources, and related issues such as premature equipment failure or unplanned downtime. The presentation will demonstrate how to identify, analyze, and minimize or eliminate harmonics problems using the ETAP software.
Obtenez un aperçu approfondi de nos logiciels d'ingénierie électrique en demandant une formation qui vous convient.
Découvrir maintenant
Testez ETAP gratuitement pendant 30 jours pour découvrir par vous-même les capacités des solutions ETAP. Essayez la vaste collection de modules et de résultats d'analyse d'ETAP sur cette plateforme de démonstration basée sur le cloud, à tout moment et en tout lieu. Commencez votre démo en ligne dès aujourd'hui !